Back to High Temperature Overview

Specify rod tip style desired. Available choices shown above.
Straight chisel tips are the most versatile, since they can be used with round or flat specimens.
MODEL 3648 High Temperature
Capacitive Extensometers (1200 °C or 1600 °C)
These extensometers feature very low specimen contact force and are available in low strain ranges for use in split type materials testing furnaces or with induction heating. Water-cooled and mounted to a slide bracket, these are for use to 1200 °C (2200 °F). The high temperature option allows use to 1600 °C (2900 °F).
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. These extensometers mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The standard temperature version (to 1200 °C) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace.
These units are made to order in many different gauge lengths and measuring ranges. The maximum travel available for any gauge length is ±2.5 mm (±0.10 inches); the minimum is ±0.25 mm (±0.01 inches).
The extensometer comes with the Model 3603 signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically.
They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
Features
- May be left on through specimen failure.
- 3603 signal conditioner and power supply included. Provides high level DC voltage output with exceptionally low noise (typical 0.1 mV on 10VDC output). Easily interfaced to test controllers, data acquisition boards, and chart recorders.
- Shipped fully calibrated with electronics (traceable to NPL (UK)) with user specified voltage output.
- All models can measure in both tension and compression and can be used for cyclic testing.
- Mechanical overtravel stops in both directions.
- All standard units meet existing ASTM class B-1 and ISO 9513, class 0,5 requirements for accuracy.
- Includes high quality foam lined case and a spare set of ceramic rods.
- Innovative slide mount allows the extensometer to engage the specimen once the test temperature has been achieved.
- Low strain range, high resolution versions available.
Model 3648 Available Versions: ANY combination of gauge length, measuring range and temperature range listed below is available, except as noted.

Specifications
Input: Includes power supply for your country (specify)Output: User specified, +/-5 VDC or +/-10 VDC typical
Linearity: 0.15% of full scale measuring range (rod length dependent)
Resolution: 0.001% of full scale
Temperature Range: Standard (-ST) is to 1200 °C (2200 °F), optional (-HT) 1600 °C (2900 °F)
Cable: Integral, ultra-flexible cable, 8 ft (2.5 m) standard
Contact Force: Adjustable up to 150 g (30-50 g typically used)
Operating Force: <10 g typical
Options
- Model 2050 Constant Temperature Water Re-Circulating Bath
- High temperature option (-HT suffix) for use to 1600°C
- Load Frame Mounting brackets
- Specify rod tip style desired. Available choice are: Straight chisel, Vee chisel, Conical tip
see larger view [+]

Model 3648 mounted to an extensometer calibrator.
Model 3648 extensometer.
Model 3648 gauge length setting mechanism.
Model 3603 electronics.




