Calibrators

 

Back to Calibrators Overview

Back to Summary of Products

  • ASTM E83 and ISO 9513 have very stringent requirements for calibrators used in extensometer calibration.
  • Most calibrators rely only on calibration of the micrometer head for system performance.
  • With Epsilon’s calibrator systems, each model is calibrated using our in-house interferometer system.
  • The 3590VHR was designed with sufficient stiffness to calibrate all Epsilon extensometers (and comparable models).
  • Calibration certificate provided with Model 3590VHR encorporates all system errors so you know the complete performance of the device you purchase, and have the confidence to perform all system critical calibrations with the device.
  • Epsilon is one of only a few companies in the world with the capability to fully calibrate complete calibrator systems.
  • contact us
  • request catalog"
  • 3590 extensometer adapters
    Model 3590 adapters.
  • 3590 extensometer group
    Model 3590VHR assemblies.

 

MODEL 3590VHR Very High Resolution
Digital Electronic Calibrators

Epsilon’s very high resolution calibrator features 0.8 microinches (20 nanometers) resolution and has 2 inches (50 mm) of measuring range. The 3590VHR is provided with a netbook PC and software to display the calibrator readings. The 3590VHR calibrator meets the accuracy and resolution requirements for ASTM E83 Class B-1 for a 6 mm gauge length and greater extensometers and ISO 9513 Class 0,5 over the full measuring range of the calibrator.

With Epsilon's in-house laser interferometer system, the full high resolution calibrator systems can be verified to ASTM E83 and ISO 9513 specifications traceable to NPL. No longer do customers have to rely on micrometer head only calibrations. With Epsilon high resolution systems, you are assured compliance. When looking for a calibrator to meet ASTM and ISO specifications, the accuracy of the device is key for compliance, which is why full system calibration is essential to meet ISO 9513 and ASTM E83 requirements. 

 

Epsilon is one of the only companies in the world with the capability to perform full system calibrations on high resolution extensometer calibrators.

The 3590VHR uses a coarse adjustment screw for large displacements, coupled with a fine adjustment screw that allows fine adjustment to withing approximately 0.025 microns (about 1 micro inch). When it comes time to calibrate your extensometers, these calibrators are easier to use and faster than any others on the market. They have enough measuring range to calibrate nearly all extensometers, and enough resolution to calibrate units with low measuring ranges.

The provided software reads in both inches and millimeters. The autozero function is a great help in calibrating. Just activate it to start readings from zero. The digital display reduces operator error.

A wide range of adapters are available. The calibrator comes with smooth round adapters, of 0.375 inches diameter (9.52 mm). For special adapters, contact Epsilon. For very long gauge length extensometers, an optional extension post is available. The calibrator is provided with a calibration traceable to NPL (UK standards organization).

3590VHR Features
(High Resolution)

  • Scale resolution: 20 nm
    (0.8 microinches)
  • Scale Accuracy:
    • ±0.19 microns (±7.5 microinches) over any 0.12 mm (0.00475 inch) range
    • Meets ASTM E83 Class B-1 for a 6 mm gauge length and greater extensometers and ISO 9513 Class 0,5 over the full measuring range of the calibrator.
  • Scale calibration traceable to NIST.
  • System fully calibrated traceable to NPL (UK standards organization).
  • 50 mm (2 inches) measuring range.
  • USB port, Netbook provided.
  • Uses the same adapters as the model 3590 and 3590HR calibrators.
  • Provided with a foam lined case for storage.

 

Options for available adapter sets
3590-01 Smooth round posts, 0.25 inches diameter (6.35 mm)
3590-02 Adapters for flat specimens
3590-03 Adapters for clip-on fracture mechanics gages
3590-04 Transverse extensometer adapters
3590-06 Adapters for large averaging extensometers
    (Model 3442RA and 3542RA)
3590-07 Extension post for long gauge length extensometers

 

 

 

 

 

 

 

 

 

 

 

 

 

contact us


 

 

  • 3590VHR extensometer
    Model 3590VHR calibrator with laser interferometer.
  • 3590VHR extensometer
    Model 3590VHR calibrator.
  • 3590VHR extensometer
    Close-up of Model 3590VHR displacement knobs.
ACCREDITATION
ISO 17025
CERTIFICATION
ISO 9001
REPRESENTATIVES
Countries Outside USA
       With Exclusive Representatives
contact us
WE ACCEPTcredit cards

ENGLISH          3975 South Highway 89, Jackson, WY 83001, USA   307 733-8360 / Fax 307 733-8375